£350 For Installers · VAT
£350 For Installers · VAT
£350 For Installers · VAT
£350 For Installers · VAT
Heat Pump Full System Design From Your Heat Loss Survey
A Complete, Install-Ready Heat Pump System Design — Produced for You
A Complete, Install-Ready Heat Pump System Design — Produced for You
A Complete, Install-Ready Heat Pump System Design — Produced for You
Heat Pump Full System Design From Your Heat Loss Survey
Send us your completed heat loss survey and we'll produce a full system design: pipe runs, system layout, component selection, cylinder specification, electrical guidance, and clear marked-up drawings ready for installation.
Send us your completed heat loss survey and we'll produce a full system design: pipe runs, system layout, component selection, cylinder specification, electrical guidance, and clear marked-up drawings ready for installation.
Send us your completed heat loss survey and we'll produce a full system design: pipe runs, system layout, component selection, cylinder specification, electrical guidance, and clear marked-up drawings ready for installation.
WHO THIS IS FOR
WHO THIS IS FOR
WHO THIS IS FOR
Council and social housing projects — where compliant, documented designs are required as part of the procurement process
Installers using third-party heat loss assessors — where the heat loss data comes from someone else and you need a full design built around it
Subcontract plumbers — working under a heat pump installer who needs a clear installation specification to follow
New-to-heat-pump installers — building confidence on early projects with a fully specified design behind them
Fast-turnaround commercial projects — where a quick, accurate design is needed to meet a programme
Council and social housing projects — where compliant, documented designs are required as part of the procurement process
Installers using third-party heat loss assessors — where the heat loss data comes from someone else and you need a full design built around it
Subcontract plumbers — working under a heat pump installer who needs a clear installation specification to follow
New-to-heat-pump installers — building confidence on early projects with a fully specified design behind them
Fast-turnaround commercial projects — where a quick, accurate design is needed to meet a programme
Council and social housing projects — where compliant, documented designs are required as part of the procurement process
Installers using third-party heat loss assessors — where the heat loss data comes from someone else and you need a full design built around it
Subcontract plumbers — working under a heat pump installer who needs a clear installation specification to follow
New-to-heat-pump installers — building confidence on early projects with a fully specified design behind them
Fast-turnaround commercial projects — where a quick, accurate design is needed to meet a programme
WHAT THIS SERVICE DELIVERS
WHAT THIS SERVICE DELIVERS
WHAT THIS SERVICE DELIVERS
This is not a review of someone else's design. This is a full system design produced from scratch, based on your heat loss survey.
You complete the heat loss survey (or provide us with a third-party assessor's results). We take that data and produce everything you need to install with confidence:
Complete pipework layout Full flow and return run design, sized correctly for the system. Primary circuit from heat pump to cylinder and headers. Distribution pipework to all zones and emitters. Clearly marked up and ready to follow on site.
Component selection Heat pump model recommendation based on heat loss and installation conditions. Cylinder specification — volume, coil sizing, immersion heater spec. Buffer vessel or low loss header inclusion and specification where required. Expansion vessel sizing.
Emitter schedule Radiator sizing validation against the design flow temperature. Identification of any radiators that require upgrading, with size recommendations. Underfloor heating circuit assessment where applicable.
Flow temperature specification Design flow temperature recommendation. Weather compensation curve settings for the specific heat pump model. Rationale for the specification.
Electrical guidance Consumer unit capacity assessment. Sub-board requirements where needed. Cable sizing and breaker selection for the heat pump and immersion heater. Any dual-tariff or smart tariff considerations.
System configuration guidance Buffer vs no buffer decision with justification. Low loss header specification where required. Zone valve and actuator recommendations. Thermostat and controller recommendations.
Commissioning targets Expected flow and return temperatures at design conditions. Target COP range. Flow rate targets for primary and secondary circuits.
This is not a review of someone else's design. This is a full system design produced from scratch, based on your heat loss survey.
You complete the heat loss survey (or provide us with a third-party assessor's results). We take that data and produce everything you need to install with confidence:
Complete pipework layout Full flow and return run design, sized correctly for the system. Primary circuit from heat pump to cylinder and headers. Distribution pipework to all zones and emitters. Clearly marked up and ready to follow on site.
Component selection Heat pump model recommendation based on heat loss and installation conditions. Cylinder specification — volume, coil sizing, immersion heater spec. Buffer vessel or low loss header inclusion and specification where required. Expansion vessel sizing.
Emitter schedule Radiator sizing validation against the design flow temperature. Identification of any radiators that require upgrading, with size recommendations. Underfloor heating circuit assessment where applicable.
Flow temperature specification Design flow temperature recommendation. Weather compensation curve settings for the specific heat pump model. Rationale for the specification.
Electrical guidance Consumer unit capacity assessment. Sub-board requirements where needed. Cable sizing and breaker selection for the heat pump and immersion heater. Any dual-tariff or smart tariff considerations.
System configuration guidance Buffer vs no buffer decision with justification. Low loss header specification where required. Zone valve and actuator recommendations. Thermostat and controller recommendations.
Commissioning targets Expected flow and return temperatures at design conditions. Target COP range. Flow rate targets for primary and secondary circuits.
This is not a review of someone else's design. This is a full system design produced from scratch, based on your heat loss survey.
You complete the heat loss survey (or provide us with a third-party assessor's results). We take that data and produce everything you need to install with confidence:
Complete pipework layout Full flow and return run design, sized correctly for the system. Primary circuit from heat pump to cylinder and headers. Distribution pipework to all zones and emitters. Clearly marked up and ready to follow on site.
Component selection Heat pump model recommendation based on heat loss and installation conditions. Cylinder specification — volume, coil sizing, immersion heater spec. Buffer vessel or low loss header inclusion and specification where required. Expansion vessel sizing.
Emitter schedule Radiator sizing validation against the design flow temperature. Identification of any radiators that require upgrading, with size recommendations. Underfloor heating circuit assessment where applicable.
Flow temperature specification Design flow temperature recommendation. Weather compensation curve settings for the specific heat pump model. Rationale for the specification.
Electrical guidance Consumer unit capacity assessment. Sub-board requirements where needed. Cable sizing and breaker selection for the heat pump and immersion heater. Any dual-tariff or smart tariff considerations.
System configuration guidance Buffer vs no buffer decision with justification. Low loss header specification where required. Zone valve and actuator recommendations. Thermostat and controller recommendations.
Commissioning targets Expected flow and return temperatures at design conditions. Target COP range. Flow rate targets for primary and secondary circuits.
WHAT YOU PROVIDE
WHAT YOU PROVIDE
WHAT YOU PROVIDE
✔ Completed heat loss survey with room-by-room results (any format)
✔ Completed heat loss survey with room-by-room results (any format)
✔ Completed heat loss survey with room-by-room results (any format)
✔ Completed heat loss survey with room-by-room results (any format)
✔ Property details — floor plan or sketch, number of storeys, construction type
✔ Property details — floor plan or sketch, number of storeys, construction type
✔ Specific issues identified with explanation and recommended action
✔ Property details — floor plan or sketch, number of storeys, construction type
✔ Existing emitter types and approximate sizes (photos acceptable)
✔ Existing emitter types and approximate sizes (photos acceptable)
✔ Existing emitter types and approximate sizes (photos acceptable)
✔ Existing emitter types and approximate sizes (photos acceptable)
✔ Installation constraints — location of plant room or utility space, external wall access, cylinder location
✔ Installation constraints — location of plant room or utility space, external wall access, cylinder location
✔ Confirmation of MCS alignment indicators
✔ Installation constraints — location of plant room or utility space, external wall access, cylinder location
✔ Any preferences regarding heat pump brand or model
✔ Any preferences regarding heat pump brand or model
✔ Confirmation of MCS alignment indicators
✔ Any preferences regarding heat pump brand or model
✔ Electrical supply details — single or three phase, consumer unit location
✔ Electrical supply details — single or three phase, consumer unit location
✔ Confirmation of MCS alignment indicators
✔ Electrical supply details — single or three phase, consumer unit location
If you're unsure what you need to provide, contact us before ordering and we'll talk you through it.
If you're unsure what you need to provide, contact us before ordering and we'll talk you through it.
If you're unsure what you need to provide, contact us before ordering and we'll talk you through it.
TURNAROUND
TURNAROUND
TURNAROUND
TURNAROUND
Standard turnaround is 5–7 working days from receipt of all required information. Fast-track turnaround (2–3 working days) is available — contact us to discuss.
Standard turnaround is 5–7 working days from receipt of all required information. Fast-track turnaround (2–3 working days) is available — contact us to discuss.
Standard turnaround is 5–7 working days from receipt of all required information. Fast-track turnaround (2–3 working days) is available — contact us to discuss.
