Heat Pump Design: What a Proper UK System Design Includes

Heat Pump Design: What a Proper UK System Design Includes

Heat Pump Design: What a Proper UK System Design Includes

Heat Pump Design: What a Proper UK System Design Includes

Heat Pump Design: What a Proper UK System Design Includes

Uk heat pump help logo

UK Heat pump Help Technical Team

Independent Heat Pump Engineer

Ask most people what heat pump design means and they will say sizing. How big a unit do I need? Sizing matters, but it is one decision in a chain of about seven, and each one affects the next. A correctly sized heat pump connected to the wrong radiators, the wrong cylinder or undersized pipework will still cost too much to run and still struggle when it gets cold.

This guide walks through what a proper air source heat pump design includes in a UK home, in the order the decisions should be made, and where quotes tend to cut corners. It is written for homeowners who are weighing up installers, and it should help you tell a design that has been thought through from one that has been filled in from a template.

What heat pump design actually means

Heat pump design is the work of planning the whole system before anything is bought or fitted. That means how much heat the house loses, what temperature the water needs to be, which radiators or underfloor heating deliver that heat, how hot water is made, how the pipework and controls are arranged, and which heat pump suits all of it. The result is a specification an installer can price and build from.

Some installers do this properly as part of their quote. Others work from a rule of thumb and a standard package. The difference tends to show up in the first winter.

Step 1: Start with the heat loss

Everything else depends on a room-by-room heat loss calculation. It looks at the walls, floor, roof, windows and ventilation in each room, then works out how much heat the house loses on a design cold day for your area, with target room temperatures that are typically around 21°C for living rooms and 18°C for bedrooms.

The total tells you what size of heat pump the house needs. The room figures matter just as much, because they decide what each radiator has to deliver later. Without this calculation the heat pump size is a guess, and an oversized unit brings its own problems, which we cover in what happens if a heat pump is oversized. If you want the detail, how a heat loss calculation is worked out and what size heat pump you need go through it step by step. It is also worth knowing why installer heat loss estimates get sizing wrong.

Step 2: Choose the flow temperature

The flow temperature is the temperature of the water leaving the heat pump to heat your home. It is the hinge of the whole design. A lower flow temperature generally means a more efficient heat pump and lower running costs, and a commonly quoted rule of thumb is a few percent better efficiency for every degree you can take off. But a lower temperature means the radiators have to be bigger, and bigger radiators cost money to buy and fit.

For most homes the sensible answer sits somewhere between 35°C and 50°C, and the right point depends on your house. A good design compares those options on both sides, installation cost and running cost, instead of picking a number and moving on. Our guides on what flow temperature a heat pump should run at and what weather compensation does explain how the temperature is set and then varied through the year.

Step 3: Check every radiator against the room it serves

Radiators are rated at a high water temperature, the kind a gas boiler runs at. At heat pump temperatures a radiator often gives only about a third to two fifths of its headline rating. That does not mean every radiator has to go. It means each one needs checking against the heat loss of its own room at the chosen flow temperature.

Most of the time the answer is mixed. Some rooms are fine as they are, some need a larger or double panel radiator, and a few may suit underfloor heating or a fan-assisted unit. Replacing everything is a common way for quotes to grow, and replacing nothing is a common way for rooms to stay cold. Underfloor heating has its own limits, because the output depends on the floor surface temperature and what the floor is covered with. For the full picture, read do heat pumps need bigger radiators.

Step 4: Plan the hot water

A heat pump heats a cylinder more gently than a boiler does, so the cylinder needs a coil large enough to transfer the heat at those lower temperatures. A heat pump rated cylinder is designed for exactly that. As a starting point, many designers allow somewhere around 40 to 50 litres per person, then adjust for how the household actually uses hot water.

An existing cylinder can sometimes stay if its coil is big enough, and that is worth checking before anyone quotes for a new one. Our guide on whether you need a hot water cylinder with a heat pump covers the options.

Step 5: Size the pipework and arrange the system

The pipework has to carry the right flow rate for the heat pump, which depends on the heat output and the temperature difference across the unit. If the pipes are too small, you get noise, a pump working too hard and, in some cases, low flow faults. The manufacturer also sets a minimum system volume so the heat pump can defrost properly, and the design has to show how the system meets it.

This is also where unnecessary parts get added. Buffer tanks, volumisers, low loss headers and extra heating zones are often fitted as standard, yet each one can add cost and sometimes cause trouble. They belong in the design only where the system needs them. See should heat pumps have buffer tanks and do heat pumps need multiple heating zones. One of our case studies shows a heat pump constantly turning on and off because of an over-zoned design, which is what this looks like in a real home.

Step 6: Decide how it will be controlled

Controls decide how the system behaves day to day. In most homes the best approach is also the simplest: weather compensation running a heating curve, with as few overrides as possible. The design should set out the control strategy so the installer commissions it as intended, rather than leaving it to whatever the equipment defaults to.

Step 7: Put it in writing

A finished design should leave you with documents an installer can work from: an equipment schedule, a schematic of the pipework and controls, and the commissioning requirements. This is what makes quotes comparable. If every installer prices the same specification, the differences in price mean something. If each one designs their own system, you are comparing three different heat pumps, three views on the radiators and three prices that do not line up. Once the quotes arrive, how to compare heat pump quotes shows what a good one includes.

Where designs get rushed

None of this means installers are careless. Many do careful work. But when a quote is built around the equipment the installer supplies, the design behind it is often quick. The usual shortcuts are a heat pump size taken from floor area or from the old boiler, radiators assumed to be fine or assumed to need replacing without a room-by-room check, and the cylinder and pipework left as whatever was there before. Each of those is a decision that has been skipped, and each one tends to come back as high bills, short cycling or rooms that never quite warm up.

Who is responsible for the design?

The installing contractor is responsible for the system they build and for any MCS requirements and certification. An independent design does not replace that. What it gives you, and the installer, is a considered specification to work from. A good installer will review it, verify the site details and then accept it or raise questions. We cannot promise automatic MCS acceptance, and you should be wary of anyone who does. For what MCS does and does not cover, read does MCS certification guarantee your heat pump is correctly sized.

Questions to ask before you accept a quote

Ask whether a room-by-room heat loss calculation has been done, and ask to see it. Ask what flow temperature the system is designed for and why that figure was chosen. Ask which radiators are being replaced and what output each room needs. Ask what size cylinder is going in and whether the coil is suited to a heat pump. Ask for a schematic showing the pipework and any buffer or zoning, and ask why those parts are there. An installer with a proper design will answer all of these without hesitation. If the answers are vague, the design probably is too.

Getting an independent design

If you would rather have the design settled before you speak to installers, that is what our independent heat pump design service is for. It is delivered remotely anywhere in the UK, quoted individually, and you are free to give the finished design to whichever installer you choose.

If you already have a quote or a proposed design and want it checked, the Pre-Installation Design Review is £295 including VAT. If you are not sure which stage you are at, when you should get an independent heat pump review will help. And if you are in Essex, Suffolk or parts of Norfolk and would like us to arrange the installation as well, take a look at our heat pump installations page.

Frequently asked questions

What is heat pump design?
It is the planning of the complete system before installation: heat loss, heat pump size, flow temperature, radiators or underfloor heating, hot water, pipework and controls. The result is a specification an installer can quote and build from.

How is heat pump design different from a heat loss calculation?
The heat loss calculation is the first step. It tells you how much heat the house needs. The design uses that figure to choose the heat pump, the flow temperature, the emitters, the cylinder, the pipework and the controls.

Can I keep my existing radiators?
Sometimes, in part. Each radiator has to be checked against the heat loss of its room at the chosen flow temperature. Rooms where it falls short need a larger radiator or another solution, and the rest can often stay.

Do I still need a design if my installer is MCS certified?
An MCS installer has to carry out a heat loss calculation and design work as part of certification, but the detail and quality vary. It is reasonable to ask to see it. An independent design is useful if you want to compare quotes for the same system or get a second view before you commit.

Can I send the design to any installer?
Yes. A standalone design can be taken to any installer. They will need to review it, check the site details and take responsibility for the final installation and certification.

Ask most people what heat pump design means and they will say sizing. How big a unit do I need? Sizing matters, but it is one decision in a chain of about seven, and each one affects the next. A correctly sized heat pump connected to the wrong radiators, the wrong cylinder or undersized pipework will still cost too much to run and still struggle when it gets cold.

This guide walks through what a proper air source heat pump design includes in a UK home, in the order the decisions should be made, and where quotes tend to cut corners. It is written for homeowners who are weighing up installers, and it should help you tell a design that has been thought through from one that has been filled in from a template.

What heat pump design actually means

Heat pump design is the work of planning the whole system before anything is bought or fitted. That means how much heat the house loses, what temperature the water needs to be, which radiators or underfloor heating deliver that heat, how hot water is made, how the pipework and controls are arranged, and which heat pump suits all of it. The result is a specification an installer can price and build from.

Some installers do this properly as part of their quote. Others work from a rule of thumb and a standard package. The difference tends to show up in the first winter.

Step 1: Start with the heat loss

Everything else depends on a room-by-room heat loss calculation. It looks at the walls, floor, roof, windows and ventilation in each room, then works out how much heat the house loses on a design cold day for your area, with target room temperatures that are typically around 21°C for living rooms and 18°C for bedrooms.

The total tells you what size of heat pump the house needs. The room figures matter just as much, because they decide what each radiator has to deliver later. Without this calculation the heat pump size is a guess, and an oversized unit brings its own problems, which we cover in what happens if a heat pump is oversized. If you want the detail, how a heat loss calculation is worked out and what size heat pump you need go through it step by step. It is also worth knowing why installer heat loss estimates get sizing wrong.

Step 2: Choose the flow temperature

The flow temperature is the temperature of the water leaving the heat pump to heat your home. It is the hinge of the whole design. A lower flow temperature generally means a more efficient heat pump and lower running costs, and a commonly quoted rule of thumb is a few percent better efficiency for every degree you can take off. But a lower temperature means the radiators have to be bigger, and bigger radiators cost money to buy and fit.

For most homes the sensible answer sits somewhere between 35°C and 50°C, and the right point depends on your house. A good design compares those options on both sides, installation cost and running cost, instead of picking a number and moving on. Our guides on what flow temperature a heat pump should run at and what weather compensation does explain how the temperature is set and then varied through the year.

Step 3: Check every radiator against the room it serves

Radiators are rated at a high water temperature, the kind a gas boiler runs at. At heat pump temperatures a radiator often gives only about a third to two fifths of its headline rating. That does not mean every radiator has to go. It means each one needs checking against the heat loss of its own room at the chosen flow temperature.

Most of the time the answer is mixed. Some rooms are fine as they are, some need a larger or double panel radiator, and a few may suit underfloor heating or a fan-assisted unit. Replacing everything is a common way for quotes to grow, and replacing nothing is a common way for rooms to stay cold. Underfloor heating has its own limits, because the output depends on the floor surface temperature and what the floor is covered with. For the full picture, read do heat pumps need bigger radiators.

Step 4: Plan the hot water

A heat pump heats a cylinder more gently than a boiler does, so the cylinder needs a coil large enough to transfer the heat at those lower temperatures. A heat pump rated cylinder is designed for exactly that. As a starting point, many designers allow somewhere around 40 to 50 litres per person, then adjust for how the household actually uses hot water.

An existing cylinder can sometimes stay if its coil is big enough, and that is worth checking before anyone quotes for a new one. Our guide on whether you need a hot water cylinder with a heat pump covers the options.

Step 5: Size the pipework and arrange the system

The pipework has to carry the right flow rate for the heat pump, which depends on the heat output and the temperature difference across the unit. If the pipes are too small, you get noise, a pump working too hard and, in some cases, low flow faults. The manufacturer also sets a minimum system volume so the heat pump can defrost properly, and the design has to show how the system meets it.

This is also where unnecessary parts get added. Buffer tanks, volumisers, low loss headers and extra heating zones are often fitted as standard, yet each one can add cost and sometimes cause trouble. They belong in the design only where the system needs them. See should heat pumps have buffer tanks and do heat pumps need multiple heating zones. One of our case studies shows a heat pump constantly turning on and off because of an over-zoned design, which is what this looks like in a real home.

Step 6: Decide how it will be controlled

Controls decide how the system behaves day to day. In most homes the best approach is also the simplest: weather compensation running a heating curve, with as few overrides as possible. The design should set out the control strategy so the installer commissions it as intended, rather than leaving it to whatever the equipment defaults to.

Step 7: Put it in writing

A finished design should leave you with documents an installer can work from: an equipment schedule, a schematic of the pipework and controls, and the commissioning requirements. This is what makes quotes comparable. If every installer prices the same specification, the differences in price mean something. If each one designs their own system, you are comparing three different heat pumps, three views on the radiators and three prices that do not line up. Once the quotes arrive, how to compare heat pump quotes shows what a good one includes.

Where designs get rushed

None of this means installers are careless. Many do careful work. But when a quote is built around the equipment the installer supplies, the design behind it is often quick. The usual shortcuts are a heat pump size taken from floor area or from the old boiler, radiators assumed to be fine or assumed to need replacing without a room-by-room check, and the cylinder and pipework left as whatever was there before. Each of those is a decision that has been skipped, and each one tends to come back as high bills, short cycling or rooms that never quite warm up.

Who is responsible for the design?

The installing contractor is responsible for the system they build and for any MCS requirements and certification. An independent design does not replace that. What it gives you, and the installer, is a considered specification to work from. A good installer will review it, verify the site details and then accept it or raise questions. We cannot promise automatic MCS acceptance, and you should be wary of anyone who does. For what MCS does and does not cover, read does MCS certification guarantee your heat pump is correctly sized.

Questions to ask before you accept a quote

Ask whether a room-by-room heat loss calculation has been done, and ask to see it. Ask what flow temperature the system is designed for and why that figure was chosen. Ask which radiators are being replaced and what output each room needs. Ask what size cylinder is going in and whether the coil is suited to a heat pump. Ask for a schematic showing the pipework and any buffer or zoning, and ask why those parts are there. An installer with a proper design will answer all of these without hesitation. If the answers are vague, the design probably is too.

Getting an independent design

If you would rather have the design settled before you speak to installers, that is what our independent heat pump design service is for. It is delivered remotely anywhere in the UK, quoted individually, and you are free to give the finished design to whichever installer you choose.

If you already have a quote or a proposed design and want it checked, the Pre-Installation Design Review is £295 including VAT. If you are not sure which stage you are at, when you should get an independent heat pump review will help. And if you are in Essex, Suffolk or parts of Norfolk and would like us to arrange the installation as well, take a look at our heat pump installations page.

Frequently asked questions

What is heat pump design?
It is the planning of the complete system before installation: heat loss, heat pump size, flow temperature, radiators or underfloor heating, hot water, pipework and controls. The result is a specification an installer can quote and build from.

How is heat pump design different from a heat loss calculation?
The heat loss calculation is the first step. It tells you how much heat the house needs. The design uses that figure to choose the heat pump, the flow temperature, the emitters, the cylinder, the pipework and the controls.

Can I keep my existing radiators?
Sometimes, in part. Each radiator has to be checked against the heat loss of its room at the chosen flow temperature. Rooms where it falls short need a larger radiator or another solution, and the rest can often stay.

Do I still need a design if my installer is MCS certified?
An MCS installer has to carry out a heat loss calculation and design work as part of certification, but the detail and quality vary. It is reasonable to ask to see it. An independent design is useful if you want to compare quotes for the same system or get a second view before you commit.

Can I send the design to any installer?
Yes. A standalone design can be taken to any installer. They will need to review it, check the site details and take responsibility for the final installation and certification.

Heat Pump Design
WhatsApp-Symbol

Contact Us

Still having heat pump problems? Talk to an engineer today.

Still having heat pump problems? Talk to an engineer today.

Still having heat pump problems? Talk to an engineer today.

Still having heat pump problems? Talk to an engineer today.

Still having heat pump problems? Talk to an engineer today.

Whether you're planning an installation, need a repair or service, or want independent advice, tell us what's happening and we'll point you in the right direction.

Whether you're planning an installation, need a repair or service, or want independent advice, tell us what's happening and we'll point you in the right direction.

Whether you're planning an installation, need a repair or service, or want independent advice, tell us what's happening and we'll point you in the right direction.

Shape